Flexural Strength Analysis

Kuat Lentur Pelat Beton Bertulang — Metode Kekuatan (LRFD)

SNI 2847:2019 SNI 1727:2020 ACI 318M

Parameter Input

Nilai default terisi, ubah bila perlu lalu klik Hitung.

Material & Geometri
MPa
mm
mm
MPa
Beban Momen
kNm/m
kNm/m
Tul. Bawah — Lapangan (Mu⁺)
Tul. Atas — Tumpuan (Mu⁻)
📄 PDF
φMn Bawah (Mu⁺)
33.8 kNm/m
φMn Atas (Mu⁻)
33.8 kNm/m
As Bawah
524 mm²/m
As Atas
524 mm²/m

Penampang Pelat & Distribusi Tulangan

tinjauan lebar 1000 mm
h = 200 mmTUL. ATAS (tumpuan / Mu⁻): D10-150TUL. BAWAH (lapangan / Mu⁺): D10-150lebar tinjau b = 1000 mm
Tul. atas (tumpuan / Mu⁻): D10-150 · 7 btg/m · As=524 mm²/m Tul. bawah (lapangan / Mu⁺): D10-150 · 7 btg/m · As=524 mm²/m

Diagram Regangan & Blok Tegangan Whitney

tiap lokasi
Bawah — Lapangan (Mu⁺)
cεcu=0.003εt=εsREGANGAN0.85f'caCcTsTEGANGAN

a=8.6 · c=10.3 · εt=0.0479 (φ=0.90)

Atas — Tumpuan (Mu⁻)
cεcu=0.003εt=εsREGANGAN0.85f'caCcTsTEGANGAN

a=8.6 · c=10.3 · εt=0.0479 (φ=0.90)

Diagram Interaksi φMn vs Jarak Tulangan

f'c 30 · fy 420
Bawah — D10 (Mu⁺=20.0)
7157432814080120160200240280Jarak tulangan s (mm)φMn (kN·m/m)Mu = 20.0s=150 · 33.8
Atas — D10 (Mu⁻=20.0)
7157432814080120160200240280Jarak tulangan s (mm)φMn (kN·m/m)Mu = 20.0s=150 · 33.8

Kurva = kapasitas φMn saat jarak divariasikan. Garis putus merah = Mu. Titik ● = konfigurasi terpilih.

Detail Perhitungan

SNI 2847:2019 Ps. 22.2 & 9
TULANGAN BAWAH — Lapangan (Mu⁺ = 20.0 kNm/m) · D10-150
1Tinggi efektif
d = h − selimut − ½·Ø = 200 − 20 − 5 = 175.0 mm
2Luas tulangan terpasang
As = ¼·π·10²·(1000/150) = 523.6 mm²/m (7 btg/m)
3a, c & regangan tarik
a = As·fy/(0.85·f'c·b) = 8.62 mm
c = a/β₁ = 10.32 mm
εt = 0.003(d−c)/c = 0.0479 → φ=0.90 ✓
4Kapasitas & cek
Mn = As·fy·(d−a/2) = 37.54 kNm/m
φMn = 0.90·Mn = 33.78 kNm/m · SR = 0.592 AMAN ✓
As,min = 583.3 mm²/m · As terpasang < As,min NG
TULANGAN ATAS — Tumpuan (Mu⁻ = 20.0 kNm/m) · D10-150
1Tinggi efektif
d = h − selimut − ½·Ø = 200 − 20 − 5 = 175.0 mm
2Luas tulangan terpasang
As = ¼·π·10²·(1000/150) = 523.6 mm²/m (7 btg/m)
3a, c & regangan tarik
a = As·fy/(0.85·f'c·b) = 8.62 mm
c = a/β₁ = 10.32 mm
εt = 0.003(d−c)/c = 0.0479 → φ=0.90 ✓
4Kapasitas & cek
Mn = As·fy·(d−a/2) = 37.54 kNm/m
φMn = 0.90·Mn = 33.78 kNm/m · SR = 0.592 AMAN ✓
As,min = 583.3 mm²/m · As terpasang < As,min NG
5Rekapitulasi Strength Ratio
LokasiTulanganMuφMnSRStatus
Lapangan (bawah)D10-15020.033.780.592AMAN
Tumpuan (atas)D10-15020.033.780.592AMAN
Dihitung berdasarkan SNI 2847:2019 — Persyaratan Beton Struktural untuk Bangunan Gedung · Metode Desain Kekuatan (LRFD).
© 2026 www.zerafo.com — Civil Engineering Tools.